Using the ResUsageSAWT table to Monitor AMP Worker Tasks - comment by dins2k2

$
0
0

Carrie,
 

Right now we have TD 14.10(6750) and we had TD 12(5550). Below is the output of DBC.ResUsageSAWT for TD 14.10

 

TheDate|VprId|Node Type|Active|InuseMax|Available|AvailableMin|AwtLimit|WorkTypeInuse00|WorkTypeInuse01
2/23/2015|-1|6750|36|38|1,424.00|17|2,880.00|266|254
4/10/2015|-1|6750|36|56|1,447.00|0|2,880.00|325|172
1/31/2015|-1|6750|36|22|1,681.00|35|2,880.00|155|36
3/30/2015|-1|6750|36|26|1,518.00|29|2,880.00|318|46
2/22/2015|-1|6750|36|10|1,728.00|45|2,880.00|33|27
 
Below id the output of PDCR.ResUsageSAWT for TD 12
TheDate|VprId|NodeType|Active|InuseMax|Available|AvailableMin|AwtLimit|WorkTypeInuse00|WorkTypeInuse01
10/29/2014|0|5550|10|28|0|0|80|12|6.4
7/13/2014|0|5550|10|59|0|0|80|24.5|19
10/4/2014|0|5550|10|39|0|0|80|8.9|7.5
5/15/2014|0|5550|10|52|0|0|80|16.9|14.1
6/24/2014|0|5550|10|30|0|0|80|6.8|5.5
 
Even I have found out the same issue in TAYS.
https://teradatanet0.teradata.com/NgwaFh5TXisD/8525621800464274/0/A6DE71759CEEE7B9852574C60067D9AD
 
I suspect the AWTLimit is completely different for both the systems. Also, I can see the MaxLoadAWT=0 for 6750 system. Is AWTLimit reason for this issue? Please shed some advise on this.
 
Thanks,
Dinesh

 